Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Selatan

Bergabung Selama :

BAGIKAN :   

Bagikan :

Hand Held Multi-Gas Detector KANE 900 PLUS

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
16 kali
Harga
Rp. 35.000.000
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Hand Held Multi-Gas Detector KANE 900 PLUS

Combustion Analyser The KANE900 PLUS handheld analyser is easy to use for domestic and industrial boiler flue gas measurement and analysis. It operates on all boiler types and can display 8 parameters simultaneously showing measurements and calculations of boiler efficiency and pollution. Measures O2, flue and nett temperature and calculates CO2, boiler efficiency, excess air and losses. CO is measured with a hydrogen compensated sensor for increased accuracy. It also measures CO and calculates CO/ CO2 ratio - ‘ The Poison Index’ - to give complete readings for effective boiler analysis and safety. Measures NO and calculates NOx. Big character display IR printer link... printed header can be customised Large memory to store results for easy transfer to PC Long life battery recharged in situ Product Features : Full combustion analyser with infra-red output to optional printer. ' Standard' instrument measures O2, CO ( hydrogen compensated) , Temperature and differential pressure. Can be upgraded with up to two additional toxic sensors. Calculates CO2, CO/ CO2 ratio, excess air and efficiency for all fuels. Fitted with rubber sleeve and rechargeable battery. Kit contents: Analyser with rubber protective sleeve Carry case. Charger KMCP10 flue probe Specification : Parameter Resolution Accuracy Range Temp Measurement Flue Temperature 0.1° C/ F + 2.0° C + 0.3% reading 0-1200° C/ 32 -2200° F with suitable probe Inlet Temperature 0.1° C/ F + 1° C + 0.3% reading 0-50° C/ 32-122° F Pressure ( optional) 0.1mbar + 2% of full scale + 150mbar to -150mbar Gas Measurement * 1 Oxygen 0.1% + 0.2% 0-25% Carbon Monoxide ( standard H compensated) 1ppm + 20ppm < 400ppm + 5% 5000ppm 0-10, 000ppm, Carbon Monoxide, ( high range) 0.01% + 5% reading from 0.1% to 10% 0-10% Nitric Oxide ( standard) 1ppm + 5ppm 100ppm 0-5000ppm Nitrogen Oxide ( low range) 1ppm + 2ppm 30ppm 0-1000ppm Nitrogen Dioxide 1ppm + 5ppm < 100ppm + 10ppm 500ppm 0-100ppm Sulphur Dioxide 1ppm + 5ppm 100ppm 0-500ppm Calculations Carbon Dioxide* 2 0.1% + 0.3% reading 0-99.9% Losses 0.1% + 1.0% reading 0-99.9% Efficiency 0.1% + 1.0% reading 0-99.9% Excess Air 0.1% + 0.2% 0-2885.0% Temp ( Nett) 1.0° C/ F + 2° C + 0.3% reading 0-600° C/ 32-1112° F CO/ CO2 ratio 0.0001 + 0.0001 0-0.9999 Poison Index 0.01% + 0.01 0-99.99 * 1 Using dry gases at STP * 2 Calculated Parameter Description Pre-programmed Fuels Natural gas, Town gas, Gascor, Light Oil, Heavy Oil, Propane, Butane, Anthracite, Coke, Coal, Kinsale Gas. Dimensions Weight 1kg Handset 220mm x 55mm x 120mm Probe L240mm x Dia8mm with 285mm long stainless steel shaft, type K thermocouple and 1.5m long neoprene hose Ambient Operating Range -5° C to + 50° C/ 10% to 90% RH non condensing Power Supply ( battery charger) Input: 110Vac/ 220 Vac nominal Output: 12 Vac off load Battery Life > 6 hours from full charge
Tampilkan Lebih Banyak