Detail Hand Held Multi-Gas Detector KANE 900 PLUS
Combustion Analyser
The KANE900 PLUS handheld analyser is easy to use for domestic and industrial boiler flue gas measurement and analysis. It operates on all boiler types and can display 8 parameters simultaneously showing measurements and calculations of boiler efficiency and pollution.
Measures O2, flue and nett temperature and calculates CO2, boiler efficiency, excess air and losses.
CO is measured with a hydrogen compensated sensor for increased accuracy.
It also measures CO and calculates CO/ CO2 ratio - ‘ The Poison Index’ - to give complete readings for effective boiler analysis and safety.
Measures NO and calculates NOx.
Big character display
IR printer link... printed header can be customised
Large memory to store results for easy transfer to PC
Long life battery recharged in situ
Product Features :
Full combustion analyser with infra-red output to optional printer.
' Standard' instrument measures O2, CO ( hydrogen compensated) ,
Temperature and differential pressure.
Can be upgraded with up to two additional toxic sensors.
Calculates CO2, CO/ CO2 ratio, excess air and efficiency for all fuels.
Fitted with rubber sleeve and rechargeable battery.
Kit contents:
Analyser with rubber protective sleeve
Carry case.
Charger
KMCP10 flue probe
Specification :
Parameter Resolution Accuracy Range
Temp Measurement
Flue Temperature 0.1° C/ F + 2.0° C + 0.3% reading 0-1200° C/ 32 -2200° F
with suitable probe
Inlet Temperature 0.1° C/ F + 1° C + 0.3% reading 0-50° C/ 32-122° F
Pressure ( optional) 0.1mbar + 2% of full scale + 150mbar
to -150mbar
Gas Measurement * 1
Oxygen 0.1% + 0.2% 0-25%
Carbon Monoxide
( standard H compensated) 1ppm + 20ppm < 400ppm
+ 5% 5000ppm 0-10, 000ppm,
Carbon Monoxide,
( high range) 0.01% + 5% reading from
0.1% to 10% 0-10%
Nitric Oxide
( standard) 1ppm + 5ppm 100ppm 0-5000ppm
Nitrogen Oxide ( low range) 1ppm + 2ppm 30ppm 0-1000ppm
Nitrogen Dioxide 1ppm + 5ppm < 100ppm
+ 10ppm 500ppm 0-100ppm
Sulphur Dioxide 1ppm + 5ppm 100ppm 0-500ppm
Calculations
Carbon Dioxide* 2 0.1% + 0.3% reading 0-99.9%
Losses 0.1% + 1.0% reading 0-99.9%
Efficiency 0.1% + 1.0% reading 0-99.9%
Excess Air 0.1% + 0.2% 0-2885.0%
Temp ( Nett) 1.0° C/ F + 2° C + 0.3% reading 0-600° C/ 32-1112° F
CO/ CO2 ratio 0.0001 + 0.0001 0-0.9999
Poison Index 0.01% + 0.01 0-99.99
* 1 Using dry gases at STP
* 2 Calculated
Parameter Description
Pre-programmed Fuels Natural gas, Town gas, Gascor, Light Oil, Heavy Oil, Propane, Butane, Anthracite, Coke, Coal, Kinsale Gas.
Dimensions Weight 1kg
Handset 220mm x 55mm x 120mm
Probe
L240mm x Dia8mm with 285mm long stainless steel shaft, type K thermocouple and 1.5m long neoprene hose
Ambient Operating Range -5° C to + 50° C/ 10% to 90% RH non condensing
Power Supply ( battery charger) Input: 110Vac/ 220 Vac nominal
Output: 12 Vac off load
Battery Life > 6 hours from full charge
Tampilkan Lebih Banyak